This project involved an owner who wanted to construct a city building between two older existing buildings. This presented a problem as the new construction could result in severe damage to these existing structures. The adjacent building owners were so concerned about the potential
damage that they, in fact, threatened legal action.
The damage concerns were mainly focused on the proposed basement of the new building. The basement would be constructed within close quarters of the existing structures which were supported on shallow foundation systems (see Figure 1). If not handled properly, construction vibrations and the undermining of these shallow foundations when installing the basement structure could result in significant damage.


After consultation with MEA’s, a UES Company, Senior Geotechnical Engineer, a solution was found. In order to provide stiff resistance against lateral movement with nominal disturbance to the adjacent structures during construction, a modified Secant Wall System was proposed. Normally this wall system consists of a line of drilled-in unreinforced concrete shafts that are then interlocked with reinforced concrete shafts (see Figure 2). However, to stiffen these drilled-in shafts, a steel I-beam was embedded into the concrete in lieu of steel reinforcement. Also, to reduce the construction difficulty and cost, the shafts were not interlocked. These 24 in. diameter drilled-in shafts had at least a clear distance on the order of 2 to 3 in. between each pile (see Figure 3). An added benefit of this wall system was that it could be structurally incorporated in the building, acting as part of the permanent basement wall and foundation for the superstructure.

Summary
This project involved construction of a new building within tight quarters of two older existing structures. As a result of the proposed immediate construction, significant concern over the associated damage to the older buildings existed. Moreover, the new building included a basement and consequently would undermine these adjacent structures. This was handled by installing a line of stiff, drilled-in concrete shafts reinforced with steel H section beams which resulted in nominal ground disturbance beneath the existing building and innocuous vibratory effects during their installation. Also, this Secant Wall System had the capability to be incorporated into the building structure.